Basic functions and features | Iotecno | Other wireless systems | Other wired systems |
1. communication between battery sensors and concentrator | 2.4G 0db/1mW low power communication doesn’t interfere other wireless monitoring systems | same for all wireless systems | serieal communication bus failure causes lost of communications for all sensors on the same string. |
2. redundency of communication between sensor and concentrator | dual-channel redundant communication channel significantly improve cmmunication reliability | only single channel, no redundancy | only single channel, no redundancy |
3. CE safety and RED EMC certified | YES | YES | normally Low Voltage Certified, no high-voltage certification on full UPS string voltage |
4. power consumption (please refer to explanation in PPT presentation about battery balance issue) | ultra-low power sensor design allows powered directly from battery (0.6mA@12v) under monitored without affecting battery balance | usually 12-20 times higher than Iotecno which is bad for battery balance | usually 12-20 times higher than Iotecno which is bad for battery balance |
5. using sleep mode to savfe power consumption | battery sensor doesn’t go into sleep mode, enable real-time response and fast alarm notification | some design go into sleep mode and only check batteryh conditions every half hour or more and lost real-time response | some design go into sleep mode and only check batteryh conditions every half hour or more and lost real-time response |
6. sensing battery temperature | directly on negative pole connector to fastest response | some designs sense only on the surface of the battery casing which is much too slow to reflect internal temperature change | some designs sense only on the surface of the battery casing which is much too slow to reflect internal temperature change |
6. fusing the battery connectors | battery cables are fused on every wires on both battery side and sensor inputs | may or may not be fused | may or may not be fused |
7. dual communication paths to centralized management systems | concentrator provides RS-485 modbus output and system controller provide both RS-485 and TCP/IP modbus outputs | most are single channel | most are single channel |
8. system flexibility | Windows CE (WEC 7) prvoide full compatibility with Windows servers system and networking | proprietory systems | proprietory systems |
Additional features: | | | |
| easy integration with other wired and wireless sensors: temperature, pressure, power, I/O control, CFD etc. | | |
| 3 groups of multi-receivers per group for email alarms | | |
| VNC remote desktop access from PC and modbile, automatic adjustment of different resolutions on mobile phone | | |
| optional SMS alarm notifications | | |